Quantity(Pieces) | 1 - 100 | >100 |
Est. Time(days) | 7 | To be negotiated |
Our business sticks for the basic principle of “Quality could be the life with the firm, and track record will be the soul of it” for OEM Supply China YUYE YES1-SA 63A-630A Automatic Transfer Switch ATS with IEC60947-6-1, Seeing believes! We sincerely welcome the new prospects abroad to set up company interactions and also expect to consolidate the interactions with all the long-established clients.
Our business sticks for the basic principle of “Quality could be the life with the firm, and track record will be the soul of it” for Automatic Transfer Switch, China ATS, now we have all day online sales to make sure the pre-sale and after-sale service in time. With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we are trying our best to be your good partner.
Model |
YES1-SA,YES1-S,YES1-L |
||||||||||
Insulation voltage |
AC690V |
||||||||||
Rated voltage |
AC400V |
||||||||||
Rated current |
20A-125A |
160A-250A |
315A-630A |
||||||||
The rated impulse withstand voltage(kV) |
8 |
||||||||||
Using classes |
AC-33iB |
||||||||||
Vote number |
Double vote |
||||||||||
Writing manner |
Before the board |
||||||||||
Pole |
2P |
3P |
4P |
2P |
3P |
4P |
2P |
3P |
4P |
||
Weight |
6 |
6.3 |
7 |
6 |
8 |
10 |
11 |
13.6 |
16.2 |
||
characteristic |
short time withstand current |
10kA
|
12.6kA |
||||||||
Connect sub-capactiy |
6le |
6le |
|||||||||
Service life |
6000times/20000times
|
1000times/4000times |
|||||||||
Operating cycle |
60times/hour |
||||||||||
Auxiliary switch |
A,B side power both with 2 normally open and 2 normally closed;switch capacity |
||||||||||
15A/AC250V |
|||||||||||
Weight(kg) |
Manual handle |
Name | Content |
Enterprise code | Shanghai Yuhuang electric co.,ltd |
Product category | PC class Automatic Transfer Switch |
Design code | 1 |
Current rank | NA/N/C:32A,125A,250A,400A,630ASA/S/LA/L:125A,250A,630AG:100A,250A,630A,1600A,3200AM:1600A AQ:3200A |
Product code | NA:16A~630A(Integral type,two positions)N:16A~630A(Split type,two positions)C:16A~630A(Split type,two positions)M:630A~1600A(Split type,two positions)Q:630A~3200A(Split type,two positions)SA:20A~630A(Integral type,Three positions)
S:20A~630A( Split type,Three positions) LA:20A~630A(Integral type,Two positions) L:20A~630A(Split type,two positions) G:GA:16A~3200A(With fire protection function) GA1:16A~100A(Without fire protection function) |
Pole | 2P(125A and below 125A products),3P,4P |
Rated current | 16A~3200A |
Working mode | R=Self-input and self-recoverS=Self-input without self-recoverF=Utility-Generator |